Attributes :
GPlus built-in ceiling split ducts have the ability to control external static pressure. This feature easily adjusts the air volume via the remote control. The BLDC motor can control fan speed and air volume regardless of external static pressure. This does not require additional equipment to control airflow.
G-Plus split ducts have an inverter compressor that maximizes energy savings by adjusting the power consumption according to the device's needs.
These devices use corrosion-resistant heat exchangers of the Blue Fin type. The blue fins are made of aluminum and are equipped with a blue coating that makes the aluminum metal coil resistant to corrosion. This feature makes the GPlus split ducts suitable for areas with acidic and alkaline air.
The GP Plus GCD-48JN6HR1 Inverter Split Inverter has the ability to connect to a hot water coil to provide hot air in the cold season.
It has a wide temperature range from -5 to +49 degrees Celsius
Equipped with digital remote control
Determining the capacity and installation of GPlus split duct
In order to determine the capacity and number of GP Plus split ducts required by the project, first send the latest architectural plan of your building units and floors via fax or email to our experts.
Usually, when estimating the cooling capacity of a duct split required for each apartment in the weather conditions such as Tehran and in the middle floors of the building (which are not exposed to sunlight to the ceiling in summer and cold roof surface in winter), every 30 or 40 The total square meter of the apartment is considered to be about one ton of refrigeration (split duct capacity) (about 400 btu / hr per square meter of useful space). So if the area of each unit of your apartment is more than 120 square meters, it is better to use two duct split devices for each unit. Also keep in mind that each BTU 12000 is equivalent to one ton of refrigeration.
For apartments up to 150 square meters, single-phase duct splits can be used, but with 32 amp power (some brands) and there is no need to request three-phase electricity (from the electricity company).
If your apartment units are even up to 200 square meters, you can use single-phase split ducts using single-phase electricity but 50 amps.
According to our experts, the manufacturers are obliged to obtain three-phase electricity for units above 200 square meters according to the directive of Tavanir Company.
One of the important points in choosing duct splits is to consider their aeration volume, which is usually suitable for each ton of duct split capacity equal to CFM 400 aeration volume. Obviously, if the aeration volume is lower, the volume of the duct split will be less, and if the aeration is higher, the volume of the duct split will be higher.